RETFLEX-FOC® RV-K 5G35 CPR Eca
RETFLEX-FOC® RV-K 5G35 CPR Eca
RETFLEX-FOC® (RV-K)
Read more- Nexans ref. : 10272203
 - Country ref. : 3427580738487
 - EAN : 10272203
 
Description
Description
Standards
- 
                                            ProductIEC 60502
 - 
                                            TestIEEE 383
 
Installation
These cables can be fixed on cable trays, within conduits or fixed to walls. They also can be buried directly with extra mechanical protection.
Core colours
- 2 cores = Brown + Light blue
 - 3 cores = Brown + Black + Grey or Light blue + Brown + Green-Yellow
 - 4 cores = Black + Grey + Brown + Light blue or Green-Yellow
 - 5 cores = Black + Light blue + Brown + Grey + Green-Yellow
 - > 5 cores = 1 Green-Yellow + others Black conductors numbered
 
Marking
Plant nr Nexans RV-K 0.6/1 kV n(G or x) s DD YYYY UNE 21123 AC RETFOC - metric marking.
- n = number of cores
 - s = section in mm²
 - DD YYYY = traceability
 - G = with Green-Yellow
 - x = without Green-Yellow
 
Gama compatible con MOBIWAY MOB
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Conductor flexibility
                                                            
                                                            
                                                                Flexible class 5 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                Bare copper 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                XLPE (chemical) 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                PVC 
                                                            
                                                        
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        
                                                                With Green/Yellow core
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Lead free
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                Circular 
                                                            
                                                        
                                                                With smaller neutral conductor
                                                            
                                                            
                                                                No 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Average insulation thickness
                                                            
                                                            
                                                                - mm
                                                            
                                                        
                                                                Number of cores
                                                            
                                                            
                                                                5 
                                                            
                                                        
                                                                Conductor cross-section
                                                            
                                                            
                                                                35 mm²
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                2077 kg/km
                                                            
                                                        
                                                                Maximum outer diameter
                                                            
                                                            
                                                                30.6 mm
                                                            
                                                        
                                                                Neutral conductor section (when smaller)
                                                            
                                                            
                                                                - mm²
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Max. DC resistance of the conductor at 20°C
                                                            
                                                            
                                                                - Ohm/km
                                                            
                                                        
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                0,6/1 kV 
                                                            
                                                        
                                                                Permissible current rating when buried
                                                            
                                                            
                                                                - A
                                                            
                                                        
                                                                Permissible current rating in open air
                                                            
                                                            
                                                                - A
                                                            
                                                        Mechanical characteristics
Mechanical characteristics
                                                                Cable flexibility
                                                            
                                                            
                                                                Flexible 
                                                            
                                                        
                                                                Mechanical resistance to impacts
                                                            
                                                            
                                                                Low 
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Chemical resistance
                                                            
                                                            
                                                                Accidental 
                                                            
                                                        
                                                                Length
                                                            
                                                            
                                                                - m
                                                            
                                                        
                                                                Max. conductor temperature in service
                                                            
                                                            
                                                                90 °C
                                                            
                                                        
                                                                Operating temperature, range
                                                            
                                                            
                                                                -5 ... 60 °C
                                                            
                                                        
                                                                Short-circuit max. conductor temperature
                                                            
                                                            
                                                                250 °C
                                                            
                                                        
                                                                Weather resistance
                                                            
                                                            
                                                                Very good 
                                                            
                                                        
                                                                Flame retardant
                                                            
                                                            
                                                                EN 50265-2-1 
                                                            
                                                        
                                                                Packaging
                                                            
                                                            
                                                                Drum 
                                                            
                                                        
                                                                Water proof
                                                            
                                                            
                                                                Good 
                                                            
                                                        Resources
Resources
Documentation
                                                    FAMILY EXPORT
                                                    xls — 0 B
                                                
                                                
                                            
                                                    PEP ECOPASSPORT RV-K 
                                                    pdf — 4.3 MB
                                                
                                                
                                            
                                                    PEP RV-K MONO
                                                    pdf — 5.0 MB
                                                
                                                
                                            
                                                    PEP RV-K MULTI
                                                    pdf — 5.0 MB
                                                
                                                
                                            
                                                    BROCHURE MOBIWAY MOB
                                                    pdf — 3.8 MB
                                                
                                                
                                            Current capacity table XLPE insulation single core three phase
| Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | Ft - Single-core trefoil cables, touching in free air | G - Single-core horizontal spaced | Gv - Single-core flat vertical spaced | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
Conductor cross-section 35.0 | 
                                            		
                                                		A1 - Insulated conductors in conduit in a thermally insulated wall
                                                	 117.0 | 
                                            		
                                                		B1 - Insulated conductors in conduit on a wooden wall
                                                	 94.0 | 
                                            		
                                                		C - Single-core or multi-core cable on a wooden wall
                                                	 144.0 | 
                                            		
                                                		D1 - Single-core or Multi-core cable in ducts in the ground
                                                	 116.0 | 
                                            		
                                                		D2 - Single-core or Multi-core cables designed to be buried directly in the ground
                                                	 147.0 | 
                                            		
                                                		F - Single-core flat cables, touching in free air
                                                	 112.0 | 
                                            		
                                                		Ft - Single-core trefoil cables, touching in free air
                                                	 115.0 | 
                                            		
                                                		G - Single-core horizontal spaced
                                                	 90.0 | 
                                            		
                                                		Gv - Single-core flat vertical spaced
                                                	 129.0 | 
                                            		mm² 98.0 | 
                                            		Cu 176.0 | 
                                            		Al 129.0 | 
                                            		Cu 169.0 | 
                                            		Al 226.0 | 
                                            		Cu 129.0 | 
                                            		Al 172.0 | 
                                            		Cu 201.0 | 
                                            		Al 153.0 | 
                                            	
Current capacity table XLPE insulation single core single phase
| Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
Conductor cross-section 35.0 | 
                                            		
                                                		A1 - Insulated conductors in conduit in a thermally insulated wall
                                                	 131.0 | 
                                            		
                                                		B1 - Insulated conductors in conduit on a wooden wall
                                                	 103.0 | 
                                            		
                                                		C - Single-core or multi-core cable on a wooden wall
                                                	 164.0 | 
                                            		
                                                		D1 - Single-core or Multi-core cable in ducts in the ground
                                                	 130.0 | 
                                            		
                                                		D2 - Single-core or Multi-core cables designed to be buried directly in the ground
                                                	 171.0 | 
                                            		
                                                		F - Single-core flat cables, touching in free air
                                                	 126.0 | 
                                            		mm² 139.0 | 
                                            		Cu 108.0 | 
                                            		Al 155.0 | 
                                            		Cu 117.0 | 
                                            		Al 200.0 | 
                                            		Cu 150.0 | 
                                            	
Current capacity table XLPE insulation multicore single phase
| Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
Conductor cross-section 35.0 | 
                                            		
                                                		A2 - Multi-core cable in conduit in a thermally insulated wall
                                                	 121.0 | 
                                            		
                                                		B2 - Multi-core cable in conduit on a wooden wall
                                                	 96.0 | 
                                            		
                                                		C - Single-core or multi-core cable on a wooden wall
                                                	 146.0 | 
                                            		
                                                		D1 - Single-core or Multi-core cable in ducts in the ground
                                                	 115.0 | 
                                            		
                                                		D2 - Single-core or Multi-core cables designed to be buried directly in the ground
                                                	 171.0 | 
                                            		
                                                		E - Multi-core cable in free air
                                                	 126.0 | 
                                            		mm² 139.0 | 
                                            		Cu 108.0 | 
                                            		Al 155.0 | 
                                            		Cu 117.0 | 
                                            		Al 185.0 | 
                                            		Cu 135.0 | 
                                            	
Current capacity table XLPE insulation multicore three phase
| Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
Conductor cross-section 35.0 | 
                                            		
                                                		A2 - Multi-core cable in conduit in a thermally insulated wall
                                                	 109.0 | 
                                            		
                                                		B2 - Multi-core cable in conduit on a wooden wall
                                                	 96.0 | 
                                            		
                                                		C - Single-core or multi-core cable on a wooden wall
                                                	 128.0 | 
                                            		
                                                		D1 - Single-core or Multi-core cable in ducts in the ground
                                                	 115.0 | 
                                            		
                                                		D2 - Single-core or Multi-core cables designed to be buried directly in the ground
                                                	 147.0 | 
                                            		
                                                		E - Multi-core cable in free air
                                                	 126.0 | 
                                            		mm² 139.0 | 
                                            		Cu 108.0 | 
                                            		Al 129.0 | 
                                            		Cu 117.0 | 
                                            		Al 185.0 | 
                                            		Cu 135.0 | 
                                            	
Declaration of Performance
- Declaration of Performance n� : 1000232-ESPO
 - Certification Date : 7/11/25
 - AVCP (Assessment and Verification of Constancy of Performance) : System 3