Nexans H07Z1-K (AS)
Nexans H07Z1-K (AS)
Nexans H07Z1-K PROTECT Type 2 (AS) is a 450/750 V halogen-free, flexible single-core insulated conductor with enhanced fire performance, compliant with EN 50525-3-31. Designed as an alternative to PVC-insulated H07V-K wiring, it is intended for protected fixed installations where both high wiring flexibility and fire safety are key selection criteria.
Its Class 5 flexible copper conductor facilitates installation in electrical panels, switchboards, trunking systems, conduits and control equipment. With its CPR classification Cca-s1,d1,a1, it meets the enhanced fire reaction requirements of sensitive buildings such as hospitals, airports, shopping centres, cinemas, schools and high-rise buildings.
Benefits
- Fire Safety: Provides up to five times greater visibility than a standard PVC-insulated wire thanks to its low smoke emission. Its halogen-free formulation limits the acidity of emitted gases and helps reduce fire propagation.
- Ease of Installation: Features a Class 5 flexible copper conductor and insulation with enhanced sliding properties, making pulling, bending and wiring easier in electrical panels, cabinets, trunking systems and conduits.
- Reduced Carbon Footprint: Environmental data available through the PEP Ecopassport® programme.
Nexans H07Z1-K Easybox 1x1.5 Blue 200m
Nexans ref. 10286790
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x1.5 Grey 200m
Nexans ref. 10286792
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x1.5 Black 200m
Nexans ref. 10286793
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x1.5 Brown 200m
Nexans ref. 10286814
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1G1.5 Green-Yellow 200m
Nexans ref. 10286815
- Packaging: Pallet (24000m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x1.5 Red 200m
Nexans ref. 10286816
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x1.5 White 200m
Nexans ref. 10286817
- Packaging: Pallet (24000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 1.5 mm²
- Approximate weight: 20 kg/km
- Outer Diameter: 2.9 mm
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Permissible current rating in open air: 18 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x2.5 Blue 200m
Nexans ref. 10286818
- Packaging: Pallet (14400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 2.5 mm²
- Approximate weight: 30 kg/km
- Outer Diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
- Permissible current rating in open air: 24 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x2.5 Black 200m
Nexans ref. 10286819
- Packaging: Pallet (14400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 2.5 mm²
- Approximate weight: 30 kg/km
- Outer Diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
- Permissible current rating in open air: 24 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x2.5 Brown 200m
Nexans ref. 10286820
- Packaging: Pallet (14400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 2.5 mm²
- Approximate weight: 30 kg/km
- Outer Diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
- Permissible current rating in open air: 24 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1G2.5 Green-Yellow 200m
Nexans ref. 10286821
- Packaging: Pallet (14400m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 2.5 mm²
- Approximate weight: 30 kg/km
- Outer Diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
- Permissible current rating in open air: 24 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x2.5 Grey 200m
Nexans ref. 10286822
- Packaging: Pallet (14400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 2.5 mm²
- Approximate weight: 30 kg/km
- Outer Diameter: 3.6 mm
- Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
- Permissible current rating in open air: 24 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x4 Blue 100m
Nexans ref. 10286823
- Packaging: Pallet (12000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 4 mm²
- Approximate weight: 45 kg/km
- Outer Diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
- Permissible current rating in open air: 32 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x4 Grey 100m
Nexans ref. 10286824
- Packaging: Pallet (12000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 4 mm²
- Approximate weight: 45 kg/km
- Outer Diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
- Permissible current rating in open air: 32 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x4 Black 100m
Nexans ref. 10286825
- Packaging: Pallet (12000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 4 mm²
- Approximate weight: 45 kg/km
- Outer Diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
- Permissible current rating in open air: 32 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x4 Brown 100m
Nexans ref. 10286826
- Packaging: Pallet (12000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 4 mm²
- Approximate weight: 45 kg/km
- Outer Diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
- Permissible current rating in open air: 32 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1G4 Green-Yellow 100m
Nexans ref. 10286827
- Packaging: Pallet (12000m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 4 mm²
- Approximate weight: 45 kg/km
- Outer Diameter: 4.2 mm
- Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
- Permissible current rating in open air: 32 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x6 Blue 100m
Nexans ref. 10286828
- Packaging: Pallet (7200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 6 mm²
- Approximate weight: 65 kg/km
- Outer Diameter: 4.7 mm
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Permissible current rating in open air: 41 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x6 Black 100m
Nexans ref. 10286829
- Packaging: Pallet (7200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 6 mm²
- Approximate weight: 65 kg/km
- Outer Diameter: 4.7 mm
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Permissible current rating in open air: 41 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1G6 Green-Yellow 100m
Nexans ref. 10286830
- Packaging: Pallet (7200m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 6 mm²
- Approximate weight: 65 kg/km
- Outer Diameter: 4.7 mm
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Permissible current rating in open air: 41 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x6 Grey 100m
Nexans ref. 10286831
- Packaging: Pallet (7200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 6 mm²
- Approximate weight: 65 kg/km
- Outer Diameter: 4.7 mm
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Permissible current rating in open air: 41 A
- Smoke density: EN 50268-2
Nexans H07Z1-K Easybox 1x6 Brown 100m
Nexans ref. 10286832
- Packaging: Pallet (7200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 6 mm²
- Approximate weight: 65 kg/km
- Outer Diameter: 4.7 mm
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Permissible current rating in open air: 41 A
- Smoke density: EN 50268-2
ALSECURE-K 1G10 Green-Yellow GL8000
Nexans ref. 10093174 - Country ref. 102 - 103 - 336
- Packaging: Pallet (8000m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1G10 Green-Yellow P5.4 R100
Nexans ref. 10072536 - Country ref. 102 - 103 - 336
- Packaging: Pallet (5400m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1x10 Blue P5.4 R100
Nexans ref. 10072535 - Country ref. 102 - 103 - 336
- Packaging: Pallet (5400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1x10 Grey P5.4 R100
Nexans ref. 10072537 - Country ref. 102 - 103 - 336
- Packaging: Pallet (5400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1x10 Black P5.4 R100
Nexans ref. 10072539 - Country ref. 102 - 103 - 336
- Packaging: Pallet (5400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1X10 Blue GL8000
Nexans ref. 10093176 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (8000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1X10 Brown GL8000
Nexans ref. 10093179 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (8000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1x10 Brown P5.4 R100
Nexans ref. 10072538 - Country ref. 102 - 103 - 336
- Packaging: Pallet (5400m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1X10 Grey GL8000
Nexans ref. 10093178 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (8000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1X10 Black GL8000
Nexans ref. 10093175 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (8000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 10 mm²
- Approximate weight: 120 kg/km
- Outer Diameter: 6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 57 A
- Smoke density: EN 50268-2
ALSECURE-K 1G16 Green-Yellow P4.2 R100
Nexans ref. 10072541 - Country ref. 102 - 103 - 336
- Packaging: Pallet (4200m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 68 A
- Smoke density: EN 50268-2
ALSECURE-K 1G16 Green-Yellow GL6000
Nexans ref. 10093181 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (6000m)
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 68 A
- Smoke density: EN 50268-2
ALSECURE-K 1x16 Blue P4.2 R100
Nexans ref. 10072540 - Country ref. 102 - 103 - 336
- Packaging: Pallet (4200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1x16 Brown P4.2 R100
Nexans ref. 10072543 - Country ref. 102 - 103 - 336
- Packaging: Pallet (4200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1x16 GreyP4.2 R100
Nexans ref. 10072542 - Country ref. 102 - 103 - 336
- Packaging: Pallet (4200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1x16 Black P4.2 R100
Nexans ref. 10072544 - Country ref. 102 - 103 - 336
- Packaging: Pallet (4200m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1X16 Blue GL6000
Nexans ref. 10093185 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (6000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1X16 Brown GL6000
Nexans ref. 10093188 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (6000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1X16 Grey GL6000
Nexans ref. 10093187 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (6000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE-K 1x16 Black GL6000
Nexans ref. 10093183 - Country ref. 102 - 103 - 336
- Packaging: Cut to length (6000m)
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 16 mm²
- Approximate weight: 175 kg/km
- Outer Diameter: 7.2 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Permissible current rating in open air: 76 A
- Smoke density: EN 50268-2
ALSECURE® H07Z1-K (AS), 1x25 mm² , blue
Nexans ref. 10072545 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 25 mm²
- Approximate weight: 25 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x25 mm², grey
Nexans ref. 10072547 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 25 mm²
- Approximate weight: 25 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x25 mm², black
Nexans ref. 10072549 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 25 mm²
- Approximate weight: 25 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x25 mm², brown
Nexans ref. 10072548 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 25 mm²
- Approximate weight: 25 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1G25 mm², Green-Yellow
Nexans ref. 10072546 - Country ref. 336
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 25 mm²
- Approximate weight: 25 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x35 mm², blue
Nexans ref. 10097989 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 35 mm²
- Approximate weight: 35 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x35 mm², black
Nexans ref. 10097990 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 35 mm²
- Approximate weight: 35 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1G35 mm², Green-Yellow
Nexans ref. 10097991 - Country ref. 103 - 336
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 35 mm²
- Approximate weight: 35 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1x50 mm², blue
Nexans ref. 10100014 - Country ref. 336
- With Green/Yellow core: No
- With smaller neutral conductor: No
- Conductor cross-section: 50 mm²
- Approximate weight: 50 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS), 1G50 mm², Green-Yellow
Nexans ref. 10100015 - Country ref. 103 - 336
- With Green/Yellow core: Yes
- With smaller neutral conductor: No
- Conductor cross-section: 50 mm²
- Approximate weight: 50 kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
ALSECURE® H07Z1-K (AS) 1x95 AV
Nexans ref. 10283813 - Country ref. 336
- With Green/Yellow core:
- With smaller neutral conductor:
- Conductor cross-section: 95 mm²
- Approximate weight: - kg/km
- Outer Diameter: - mm
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible current rating in open air: - A
- Smoke density: IEC 61034-2
Description
Description
Standards
-
ProductEN 50525-3-31; EN 50575; IEC 60228; UNE 21022; UNE 211002
-
InstallationNF C15-100
-
TestEN 50266-2-4; EN 50267-2-2; EN 50399; EN 60754-2; IEC 60332-1-2; IEC 60332-3-24; IEC 61034-2; NF C32-070/C2; UNE EN 50267-2-3 ; UNE-EN 50265-2-1
Application
Nexans H07Z1-K PROTECT Type 2 (AS) is designed for protected low-voltage fixed installations. It is suitable for the wiring of electrical panels, switchboards, control equipment, electrical apparatus and circuits installed in conduits or trunking.
Its Class 5 flexible copper conductor facilitates installation in applications requiring enhanced flexibility, such as compact switchboards, industrial and commercial cabinets, internal equipment wiring and colour-coded circuits.
The halogen-free, low-smoke insulation makes it particularly suitable for installations in buildings where fire safety requirements are critical, including public buildings, high-rise buildings, residential complexes, schools, healthcare facilities, commercial premises and protected industrial environments.
Installation
Nexans H07Z1-K PROTECT Type 2 (AS) is intended for protected indoor fixed installations in conduits, ducts, trunking systems, raceways, skirting-board trunking, mouldings or similar closed systems, either surface-mounted or concealed, in accordance with applicable installation practices and regulations. It may also be used for the internal wiring of electrical panels, switchboards, electrical apparatus and control equipment, provided compatibility with terminals and applicable wiring rules is ensured. It is not intended for direct outdoor installation, direct burial, immersion, or for mobile applications or installations subject to repeated flexing.
Recommended installation:
- Minimum installation temperature: +5 °C
- Minimum bending radius: 4 × D for fixed installation
- Maximum pulling force: 50 N/mm² of copper cross-section
Encuentra este producto en EASYCALC™
New cardboard packaging for H07V-K and H07Z1-K
Color code for Nexans Alsecure H07Z1-K cross-section
Cable colors available
-
-
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Current capacity table PVC insulation multicore three phase
| Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 13.0 | 0.0 | 15.0 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 18.5 | 0.0 |
| 2.5 | 17.5 | 13.5 | 20.0 | 15.5 | 24.0 | 18.5 | 24.0 | 18.5 | 24.0 | 0.0 | 25.0 | 19.5 |
| 4.0 | 23.0 | 17.5 | 27.0 | 21.0 | 32.0 | 25.0 | 30.0 | 24.0 | 33.0 | 0.0 | 34.0 | 26.0 |
| 6.0 | 29.0 | 23.0 | 34.0 | 27.0 | 41.0 | 32.0 | 38.0 | 30.0 | 41.0 | 0.0 | 43.0 | 33.0 |
| 10.0 | 39.0 | 31.0 | 46.0 | 36.0 | 57.0 | 44.0 | 50.0 | 39.0 | 54.0 | 0.0 | 60.0 | 46.0 |
| 16.0 | 52.0 | 41.0 | 62.0 | 48.0 | 76.0 | 59.0 | 64.0 | 50.0 | 70.0 | 53.0 | 80.0 | 61.0 |
| 25.0 | 68.0 | 53.0 | 80.0 | 62.0 | 96.0 | 73.0 | 82.0 | 64.0 | 92.0 | 69.0 | 101.0 | 78.0 |
| 35.0 | 83.0 | 65.0 | 99.0 | 77.0 | 119.0 | 90.0 | 98.0 | 77.0 | 110.0 | 83.0 | 126.0 | 96.0 |
| 50.0 | 99.0 | 78.0 | 118.0 | 92.0 | 144.0 | 110.0 | 116.0 | 91.0 | 130.0 | 99.0 | 153.0 | 117.0 |
| 70.0 | 125.0 | 98.0 | 149.0 | 116.0 | 184.0 | 140.0 | 143.0 | 112.0 | 162.0 | 122.0 | 196.0 | 150.0 |
| 95.0 | 150.0 | 118.0 | 179.0 | 139.0 | 223.0 | 170.0 | 169.0 | 132.0 | 193.0 | 148.0 | 238.0 | 183.0 |
| 120.0 | 172.0 | 135.0 | 206.0 | 160.0 | 259.0 | 197.0 | 192.0 | 150.0 | 220.0 | 169.0 | 276.0 | 212.0 |
| 150.0 | 196.0 | 155.0 | 225.0 | 176.0 | 299.0 | 227.0 | 217.0 | 169.0 | 246.0 | 189.0 | 319.0 | 245.0 |
| 185.0 | 223.0 | 176.0 | 255.0 | 199.0 | 341.0 | 259.0 | 243.0 | 190.0 | 278.0 | 214.0 | 364.0 | 280.0 |
| 240.0 | 261.0 | 207.0 | 297.0 | 232.0 | 403.0 | 305.0 | 280.0 | 218.0 | 320.0 | 250.0 | 430.0 | 330.0 |
| 300.0 | 298.0 | 237.0 | 339.0 | 265.0 | 464.0 | 351.0 | 316.0 | 247.0 | 359.0 | 282.0 | 497.0 | 381.0 |
Current capacity table PVC insulation multicore single phase
| Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 14.0 | 0.0 | 16.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 |
| 2.5 | 18.5 | 14.5 | 23.0 | 17.5 | 27.0 | 21.0 | 27.0 | 22.0 | 28.0 | 0.0 | 30.0 | 23.0 |
| 4.0 | 25.0 | 19.5 | 30.0 | 24.0 | 36.0 | 28.0 | 37.0 | 29.0 | 38.0 | 0.0 | 40.0 | 31.0 |
| 6.0 | 32.0 | 25.0 | 38.0 | 30.0 | 46.0 | 36.0 | 46.0 | 36.0 | 48.0 | 0.0 | 51.0 | 39.0 |
| 10.0 | 43.0 | 33.0 | 52.0 | 41.0 | 63.0 | 49.0 | 60.0 | 47.0 | 64.0 | 0.0 | 70.0 | 54.0 |
| 16.0 | 57.0 | 44.0 | 69.0 | 54.0 | 85.0 | 66.0 | 78.0 | 61.0 | 83.0 | 63.0 | 94.0 | 73.0 |
| 25.0 | 75.0 | 58.0 | 90.0 | 71.0 | 112.0 | 83.0 | 99.0 | 77.0 | 110.0 | 82.0 | 119.0 | 89.0 |
| 35.0 | 92.0 | 71.0 | 111.0 | 86.0 | 138.0 | 103.0 | 119.0 | 93.0 | 132.0 | 98.0 | 148.0 | 111.0 |
| 50.0 | 110.0 | 86.0 | 133.0 | 104.0 | 168.0 | 125.0 | 140.0 | 109.0 | 156.0 | 117.0 | 180.0 | 135.0 |
| 70.0 | 139.0 | 108.0 | 168.0 | 131.0 | 213.0 | 160.0 | 173.0 | 135.0 | 192.0 | 145.0 | 232.0 | 173.0 |
| 95.0 | 167.0 | 130.0 | 201.0 | 157.0 | 258.0 | 195.0 | 204.0 | 159.0 | 230.0 | 173.0 | 282.0 | 210.0 |
| 120.0 | 192.0 | 150.0 | 232.0 | 181.0 | 299.0 | 226.0 | 231.0 | 180.0 | 261.0 | 200.0 | 328.0 | 244.0 |
| 150.0 | 219.0 | 172.0 | 258.0 | 201.0 | 344.0 | 261.0 | 261.0 | 204.0 | 293.0 | 224.0 | 379.0 | 282.0 |
| 185.0 | 248.0 | 195.0 | 294.0 | 230.0 | 392.0 | 298.0 | 292.0 | 228.0 | 331.0 | 255.0 | 434.0 | 322.0 |
| 240.0 | 291.0 | 229.0 | 344.0 | 269.0 | 461.0 | 352.0 | 336.0 | 262.0 | 382.0 | 298.0 | 514.0 | 380.0 |
| 300.0 | 334.0 | 263.0 | 394.0 | 308.0 | 530.0 | 406.0 | 379.0 | 296.0 | 427.0 | 336.0 | 593.0 | 439.0 |
Current capacity table PVC insulation single core three phase
| Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | Ft - Single-core trefoil cables, touching in free air | G - Single-core horizontal spaced | Gv - Single-core flat vertical spaced | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 13.5 | 0.0 | 15.5 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 2.5 | 18.0 | 14.0 | 21.0 | 16.5 | 24.0 | 18.5 | 24.0 | 18.5 | 24.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 4.0 | 24.0 | 18.5 | 28.0 | 22.0 | 32.0 | 25.0 | 30.0 | 24.0 | 33.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 6.0 | 31.0 | 24.0 | 36.0 | 28.0 | 41.0 | 32.0 | 38.0 | 30.0 | 41.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 10.0 | 42.0 | 32.0 | 50.0 | 39.0 | 57.0 | 44.0 | 50.0 | 39.0 | 54.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 16.0 | 56.0 | 43.0 | 68.0 | 53.0 | 76.0 | 59.0 | 64.0 | 50.0 | 70.0 | 53.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 25.0 | 73.0 | 57.0 | 89.0 | 70.0 | 96.0 | 73.0 | 82.0 | 64.0 | 92.0 | 69.0 | 114.0 | 87.0 | 110.0 | 146.0 | 84.0 | 112.0 | 130.0 | 99.0 |
| 35.0 | 89.0 | 70.0 | 110.0 | 86.0 | 119.0 | 90.0 | 98.0 | 77.0 | 110.0 | 83.0 | 143.0 | 109.0 | 137.0 | 181.0 | 105.0 | 139.0 | 162.0 | 124.0 |
| 50.0 | 106.0 | 84.0 | 134.0 | 104.0 | 144.0 | 110.0 | 116.0 | 91.0 | 130.0 | 99.0 | 174.0 | 133.0 | 167.0 | 219.0 | 128.0 | 169.0 | 197.0 | 152.0 |
| 70.0 | 138.0 | 107.0 | 171.0 | 133.0 | 184.0 | 140.0 | 143.0 | 112.0 | 162.0 | 122.0 | 225.0 | 173.0 | 216.0 | 281.0 | 166.0 | 217.0 | 254.0 | 196.0 |
| 95.0 | 164.0 | 129.0 | 207.0 | 161.0 | 223.0 | 170.0 | 169.0 | 132.0 | 193.0 | 148.0 | 275.0 | 212.0 | 264.0 | 341.0 | 203.0 | 265.0 | 311.0 | 241.0 |
| 120.0 | 188.0 | 149.0 | 239.0 | 186.0 | 259.0 | 197.0 | 192.0 | 150.0 | 220.0 | 169.0 | 321.0 | 247.0 | 308.0 | 396.0 | 237.0 | 308.0 | 362.0 | 282.0 |
| 150.0 | 216.0 | 170.0 | 262.0 | 204.0 | 299.0 | 227.0 | 217.0 | 169.0 | 246.0 | 189.0 | 372.0 | 287.0 | 356.0 | 456.0 | 274.0 | 356.0 | 419.0 | 327.0 |
| 185.0 | 245.0 | 194.0 | 296.0 | 230.0 | 341.0 | 259.0 | 243.0 | 190.0 | 278.0 | 214.0 | 427.0 | 330.0 | 409.0 | 521.0 | 315.0 | 407.0 | 480.0 | 376.0 |
| 240.0 | 286.0 | 227.0 | 346.0 | 269.0 | 403.0 | 305.0 | 280.0 | 218.0 | 320.0 | 250.0 | 507.0 | 392.0 | 485.0 | 615.0 | 375.0 | 482.0 | 569.0 | 447.0 |
| 300.0 | 328.0 | 261.0 | 394.0 | 306.0 | 464.0 | 351.0 | 316.0 | 247.0 | 359.0 | 282.0 | 587.0 | 455.0 | 561.0 | 709.0 | 434.0 | 557.0 | 659.0 | 519.0 |
Current capacity table PVC insulation single core single phase
| Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
| 1.5 | 14.5 | 0.0 | 17.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 0.0 | 0.0 |
| 2.5 | 19.5 | 15.0 | 24.0 | 18.5 | 27.0 | 21.0 | 29.0 | 22.0 | 28.0 | 0.0 | 0.0 | 0.0 |
| 4.0 | 26.0 | 20.0 | 32.0 | 25.0 | 36.0 | 28.0 | 37.0 | 29.0 | 38.0 | 0.0 | 0.0 | 0.0 |
| 6.0 | 34.0 | 26.0 | 41.0 | 32.0 | 46.0 | 36.0 | 46.0 | 36.0 | 48.0 | 0.0 | 0.0 | 0.0 |
| 10.0 | 46.0 | 36.0 | 57.0 | 44.0 | 63.0 | 49.0 | 60.0 | 47.0 | 64.0 | 0.0 | 0.0 | 0.0 |
| 16.0 | 61.0 | 48.0 | 76.0 | 60.0 | 85.0 | 66.0 | 78.0 | 61.0 | 83.0 | 63.0 | 0.0 | 0.0 |
| 25.0 | 80.0 | 63.0 | 101.0 | 79.0 | 112.0 | 83.0 | 99.0 | 77.0 | 110.0 | 82.0 | 131.0 | 98.0 |
| 35.0 | 99.0 | 77.0 | 125.0 | 97.0 | 138.0 | 103.0 | 119.0 | 93.0 | 132.0 | 98.0 | 162.0 | 122.0 |
| 50.0 | 119.0 | 93.0 | 151.0 | 118.0 | 168.0 | 125.0 | 140.0 | 109.0 | 156.0 | 117.0 | 196.0 | 149.0 |
| 70.0 | 151.0 | 118.0 | 192.0 | 150.0 | 213.0 | 160.0 | 173.0 | 135.0 | 192.0 | 145.0 | 251.0 | 192.0 |
| 95.0 | 182.0 | 142.0 | 232.0 | 181.0 | 258.0 | 195.0 | 204.0 | 159.0 | 230.0 | 173.0 | 304.0 | 235.0 |
| 120.0 | 210.0 | 164.0 | 269.0 | 210.0 | 299.0 | 226.0 | 231.0 | 180.0 | 261.0 | 200.0 | 352.0 | 273.0 |
| 150.0 | 240.0 | 189.0 | 300.0 | 234.0 | 344.0 | 261.0 | 261.0 | 204.0 | 293.0 | 224.0 | 406.0 | 316.0 |
| 185.0 | 273.0 | 215.0 | 341.0 | 266.0 | 392.0 | 298.0 | 292.0 | 228.0 | 331.0 | 255.0 | 463.0 | 363.0 |
| 240.0 | 321.0 | 252.0 | 400.0 | 312.0 | 461.0 | 352.0 | 336.0 | 262.0 | 382.0 | 298.0 | 546.0 | 430.0 |
| 300.0 | 367.0 | 289.0 | 458.0 | 358.0 | 530.0 | 406.0 | 379.0 | 296.0 | 427.0 | 336.0 | 629.0 | 497.0 |